;+
;NAME: barrel_load_fspc
;DESCRIPTION: CDF-to-TDAS import routine for BARREL fast-speed spectral
; (FSPC) data products (also 'FSPEC')
;
;REQUIRED INPUTS:
; none
;
;KEYWORD ARGUMENTS (OPTIONAL):
; PROBE: String [array] of BARREL identifiers (e.g., '1A', '1B').
; Default is 'all' (i.e., all available payloads). May also be
; a single string delimited by spaces (e.g., '1A 1B').
; DATATYPE: String [array] of BARREL datatype identifiers (e.g. 'FSPC').
; TRANGE: Time range for tplot (2 element array). Loads data in whole-day
; chunks, and will prompt user if not specified.
; LEVEL: String [array] of data level code (e.g. 'l1', 'l2').
; VERSION: String specifying data revision number (e.g. 'v01', 'v02').
; /VERBOSE:
; CDF_DATA: (not implemented)
; /GET_SUPPORT_DATA: Load support_data variables as well as data variables.
; TPLOTNAMES: (passed through to 'cdf2tplot' and 'cdf_info_to_tplot')
; MAKE_MULTI_TPLOTVAR: (not implemented)
; VARFORMAT: String (passed through to 'cdf2tplot').
; /VALID_NAMES: (not implemented)
; FILES: (not implemented)
;
; (FILE_RETRIEVE KEYWORDS-- descriptions borrowed from file_retrieve.pro)
; /DOWNLOADONLY:
; Set to 1 to only download files but not load files into memory.
; /NO_SERVER: Set to 1 to prevent any contact with a remote server.
; /NO_DOWNLOAD: Identical to NO_SERVER keyword. Obsolete, but retained for backward compatibility
; /NO_UPDATE: Set to 1 to prevent contact to server if local file already exists. (this is similar to no_clobber)
; /NO_CLOBBER: Set to 1 to prevent existing files from being overwritten. (A warning message will be displayed if remote server has)
;
;OUTPUTS:
; none
;
;STATUS:
;
;TO BE ADDED: n/a
;
;EXAMPLE:
;
;REVISION HISTORY:
;Version 0.96a KBY 06/15/2014 fixed bug in FSPC1 reconstruction routine (campaign 1 compatibility)
;Version 0.95b KBY 12/29/2013 recreation of FSPC1 channel from FSPC1a + FSPC1b + FSPC1c components
;Version 0.95a KBY 12/27/2013 preliminary support for new FSPC variables "FSPC1a", "FSPC1b", "FSPC1c"
;Version 0.94a KBY 09/13/2013 support for new FSPC variable "FSPC_Edges"
;Version 0.93e KBY 08/28/2013 support for noting VALID_MIN and VALID_MAX values;
; rename 'LCx' variables to 'FSPCx'
;Version 0.93d KBY 08/23/2013 quality indicator ("Q") renamed "Quality";
; take unit labels from CDF metadata; update documentation.
;Version 0.93c KBY 08/23/2013 BARREL payload identifiers shortened to alphanumeric build
; order only (e.g., '1A', '1B'), following change to CDF naming convention
;Version 0.93a KBY 08/16/2013 accomodate v02 CDF namechange of "LC[1-4]_ERROR" to "cnt_error[1-4]";
; specify default value for "units"
;Version 0.92 KBY 06/04/2013 introduced VERSION keyword
;Version 0.91c KBY 05/31/2013 handling of ISTP fill values
;Version 0.91b KBY 05/31/2013 check for and delete existing variables of same name
;Version 0.91a KBY 05/28/2013 added file_retrieve keywords (no_download/update/clobber)
;Version 0.90a KBY 04/19/2013 re-factoring of generic load actions; update CDF compatibility
;Version 0.83 KBY 11/28/2012 initial beta release
;Version 0.82 KBY 11/27/2012 debugging with updated CDF definitions
;Version 0.81 KBY 11/21/2012 new CDF definitions; updated treatment of PROBE
; keyword; distinction between L1 and L2 data product handling.
;Version 0.8 KBY 10/29/2012 from 'rbsp_load_efw_spec.pro' (Peter Schroeder),
; and 'thm_load_goesmag.pro'
;
;-
pro barrel_load_fspc, probe=probe, datatype=datatype, trange=trange, $
level=level, version=version, verbose=verbose, $
downloadonly=downloadonly, $
no_download=no_download, no_server=no_server, $
no_update=no_update, no_clobber=no_clobber, $
cdf_data=cdf_data, get_support_data=get_support_data, $
tplotnames=tns, make_multi_tplotvar=make_multi_tplotvar, $
varformat=varformat, valid_names=valid_names, files=files, $
CONVERT_L1_TO_PHYSICAL_UNITS=do_convert_L1
; specify VDATATYPES and VLEVELS for FSPC
vlevels = ['l2','l1'] ; Zeroth element is our default (require only one level)
vdatatypes = ['fspc'] ; Require only one datatype at this level
; submit request for PROBE, LEVEL, and DATATYPE
return_value = barrel_preload_actions(probe=probe,datatype=datatype,$
trange=trange,level=level,version=version, $
vdatatypes=vdatatypes,vlevels=vlevels,$
verbose=verbose,get_support_data=get_support_data,$
downloadonly=downloadonly, $
no_download=no_download, no_server=no_server, $
no_update=no_update, no_clobber=no_clobber, $
tplotnames=tns,varformat=varformat,$
valid_names=valid_names,files=files)
; variables have been loaded from CDF to TDAS
new_tpvars = return_value.tplot_variables ; string array of TPLOT variable handles
level = return_value.level ; the level that was loaded
not_empty = WHERE(new_tpvars, n_newvars)
; if necessary, calculate FSPC1 from components (FSPC1a + FSPC1b + FSPC1c)
IF (n_newvars GT 0) THEN BEGIN
breakpt = 6
balloons = STRMID(new_tpvars,0,breakpt)
sorted_balloons = balloons[SORT(balloons)]
unique_vector = UNIQ(sorted_balloons)
; loop over balloons
FOR i=0, N_ELEMENTS(unique_vector)-1 DO BEGIN
pre = sorted_balloons[unique_vector[i]]
required = [pre+'FSPC1a',pre+'FSPC1b',pre+'FSPC1c']
matching_names = strfilter(new_tpvars, required)
sorted_names = matching_names[SORT(matching_names)]
three_vector = UNIQ(sorted_names)
fspc1_exists = (N_ELEMENTS(strfilter(new_tpvars, pre+'FSPC1')) GT 0)
; test for prerequisites
IF (~fspc1_exists) AND (N_ELEMENTS(three_vector) EQ 3) THEN BEGIN
; an "FSPC1" variable does not exist.. attempt to calculate it
get_data, sorted_names[three_vector[0]], DATA=lc1a, LIMITS=l_str, DLIMITS=dl_str
get_data, sorted_names[three_vector[1]], DATA=lc1b
get_data, sorted_names[three_vector[2]], DATA=lc1c
; ensure that a comparison is valid.
; Require:
; 1. same number of elements
; 2. the elements of each time series are actually identical
;req_dims = SIZE(b0.x, /DIMENSIONS)
;pass_req1 = (SIZE(b1.x, /DIMENSIONS) EQ req_dims) $
; AND (SIZE(b2.x, /DIMENSIONS) EQ req_dims)
;pass_req2 = (TOTAL(b0.x NE b1.x) EQ 0) $
; AND (TOTAL(b0.x NE b2.x) EQ 0)
pass_both_reqs = ARRAY_EQUAL(lc1a.x, lc1b.x) AND ARRAY_EQUAL(lc1a.x, lc1c.x)
;IF (pass_req1 AND pass_req2) THEN BEGIN
IF (pass_both_reqs) THEN BEGIN
; assume that the y-dimensions are also valid / appropriately sized
fspc1 = (lc1a.y + lc1b.y + lc1c.y)
store_data, pre+'FSPC1', DATA={x:lc1a.x, y:fspc1}, LIMITS=l_str, DLIMITS=dl_str
new_tpvars = [new_tpvars, pre+'FSPC1']
n_newvars += 1
ENDIF ELSE print, 'barrel_load_fspc: mismatched FSPC 1a/1b/1c entries-- no FSPC1 calculated'
ENDIF
ENDFOR
ENDIF
not_empty = WHERE(new_tpvars, n_newvars)
; post-load variable configuration
IF (n_newvars GT 0) THEN BEGIN
tplotnames = new_tpvars[not_empty]
FOR i=0, N_ELEMENTS(tplotnames)-1 DO BEGIN
tplot_var = tplotnames[i]
get_data, tplot_var, data=d_str, limit=l_str, dlimit=dl_str
; if data is of type "data" or "support_data", we may want to customize it
IF size(/type, dl_str) EQ 8 && ((dl_str.cdf.vatt.var_type EQ 'data') OR $
(dl_str.cdf.vatt.var_type EQ 'support_data')) THEN BEGIN
; build and populate a minimal dl_str.data_att
thm_new_units, tplot_var
thm_new_coords, tplot_var
str_element, dl_str, 'data_att', success=yes_data_att
IF ~yes_data_att THEN BEGIN
data_att = {units:'', coord_sys:'none'}
str_element, dl_str, 'data_att', data_att, /add
ENDIF
; Add 'none' to coord_sys if it doesn't exist
str_element, dl_str.data_att, 'coord_sys', success=yes_coord
IF yes_coord THEN coord=dl_str.data_att.coord_sys
; FSPC-class variables have name structure:
; brlPP_VARIABLE
;
; where 'brlPP' is the per-payload identifier, designating..
; brl = mission identifier (BARREL)
; PP = alphanumerical payload identifier (build order)
; Note: the numerical part PP doubles as a campaign identifier
; C = campaign identifier (1=2012-2013, 2=2012-2013)
;
; and VARIABLE designates the relevant FSPC-class variable
; FSPC1 (LC1)
; FSPC1a (subchannel of FSPC1 [campaign 2 only])
; FSPC1b (subchannel of FSPC1 [campaign 2 only])
; FSPC1c (subchannel of FSPC1 [campaign 2 only])
; FSPC2 (LC2
; FSPC3 (LC3)
; FSPC4 (LC4)
; FSPC_cnt_error1 (standard error in LC1 countrate)
; FSPC_cnt_error1a (standard error in LC1a countrate)
; FSPC_cnt_error1b (standard error in LC1b countrate)
; FSPC_cnt_error1c (standard error in LC1c countrate)
; FSPC_cnt_error2 (standard error in LC2 countrate)
; FSPC_cnt_error3 (standard error in LC3 countrate)
; FSPC_cnt_error4 (standard error in LC4 countrate)
; FSPC_Edges (calibrated bin boundaries)
; FSPC_FrameGroup
; FSPC_Quality
; extract useful information from CDF metadata..
; 1) test for existence of the "dl_str.cdf.vatt.UNITS" tag
str_element, dl_str.cdf.vatt, 'units', units_test, success = units_do_exist
IF (units_do_exist) THEN unit = units_test $ ; set default to CDF specification
ELSE unit = 'none' ; set default units to 'none'
; 2) test for existence of the "dl_str.cdf.vatt.LABLAXIS" tag
str_element, dl_str.cdf.vatt, 'lablaxis', label_test, success = label_does_exist
IF (label_does_exist) THEN labels = label_test $ ; set default to CDF specification
ELSE labels = 'none' ; set default label to 'none'
; 3) test for existence of the "dl_str.cdf.vatt.FILLVAL" tag
str_element, dl_str.cdf.vatt, 'fillval', fillval_test, success = fillval_does_exist
IF (fillval_does_exist) THEN max_fillvalue = fillval_test $ ; set default to CDF specification
ELSE max_fillvalue = !Values.F_NAN ; set default to NaN
; 4) test for existence of the "dl_str.cdf.vatt.VALIDMIN" tag
str_element, dl_str.cdf.vatt, 'validmin', validmin, success = validmin_does_exist
; 5) test for existence of the "dl_str.cdf.vatt.VALIDMAX" tag
str_element, dl_str.cdf.vatt, 'validmax', validmax, success = validmax_does_exist
; handling of ISTP fill values (all of FSPC should be immune)
;max_fillvalue = -32768 ; generic non-negative
fill2nan = 0 ; not applicable
breakpt = 6
CASE STRMID(tplot_var,breakpt) OF
'FrameGroup': BEGIN
colors=0
; rename with inserted class identifier
new_name = STRMID(tplot_var,0,breakpt)+'FSPC_'+$
STRMID(tplot_var,breakpt)
; search for existing variables, and delete
exists = tnames(new_name, cnt)
IF (cnt NE 0) THEN store_data, new_name, /DELETE
; rename as appropriate
store_data, tplot_var, NEWNAME=new_name
tplot_var = new_name
END
'Quality': BEGIN
colors=0
; rename with inserted class identifier
new_name = STRMID(tplot_var,0,breakpt)+'FSPC_'+$
STRMID(tplot_var,breakpt)
; search for existing variables, and delete
exists = tnames(new_name, cnt)
IF (cnt NE 0) THEN store_data, new_name, /DELETE
; rename as appropriate
store_data, tplot_var, NEWNAME=new_name
tplot_var = new_name
END
'FSPC1': BEGIN ; fast spectrum 1 / lightcurve 1
colors = 2
; if recreated from sum of [FSPC1a/1b/1c], fix labels
IF (dl_str.cdf.vname EQ 'FSPC1a') THEN BEGIN
; assume that everything else also needs to be changed..
str_element, dl_str, 'cdf.VNAME', 'FSPC1', /ADD_REPLACE
str_element, dl_str, 'cdf.vatt.FIELDNAM', 'FSPC1', /ADD_REPLACE
str_element, dl_str, 'cdf.vatt.CATDESC', $
'Fast spectra (50ms) ch. 1 (reconstructed)', /ADD_REPLACE
str_element, dl_str, 'cdf.vatt.LABLAXIS', 'FSPC1', /ADD_REPLACE
str_element, dl_str, 'cdf.vatt.DELTA_PLUS_VAR', 'none (not reconstructed)', /ADD_REPLACE
str_element, dl_str, 'cdf.vatt.DELTA_MINUS_VAR', 'none (not recontructed)', /ADD_REPLACE
;str_element, dl_str, 'LABELS', 'FSPC1', /ADD_REPLACE
labels = 'FSPC1' ; as this gets written out later
ENDIF
END
'FSPC1a': BEGIN ; fast spectrum 1a / lightcurve 1a [campaign 2 only]
colors = 1 ;(alternate LOADCT2 colors: magenta)
END
'FSPC1b': BEGIN ; fast spectrum 1b / lightcurve 1b [campaign 2 only]
colors = 3 ;(alternate LOADCT2 colors: cyan)
END
'FSPC1c': BEGIN ; fast spectrum 1c / lightcurve 1c [campaign 2 only]
colors = 5 ;(alternate LOADCT2 colors: yellow)
END
'FSPC2': BEGIN ; fast spectrum 2 / lightcurve 2
colors = 4
END
'FSPC3': BEGIN ; fast spectrum 3 / lightcurve 3
colors = 6
END
'FSPC4': BEGIN ; fast spectrum 4 / lightcurve 4
colors = 8
END
'cnt_error1': BEGIN
colors = 1
; rename with inserted class identifier
new_name = STRMID(tplot_var,0,breakpt)+'FSPC_'+$
STRMID(tplot_var,breakpt)
; search for existing variables, and delete
exists = tnames(new_name, cnt)
IF (cnt NE 0) THEN store_data, new_name, /DELETE
; rename as appropriate
store_data, tplot_var, NEWNAME=new_name
tplot_var = new_name
END
'cnt_error1a': BEGIN
; a L2 product only
colors = 1
; rename with inserted class identifier
new_name = STRMID(tplot_var,0,breakpt)+'FSPC_'+$
STRMID(tplot_var,breakpt)
; search for existing variables, and delete
exists = tnames(new_name, cnt)
IF (cnt NE 0) THEN store_data, new_name, /DELETE
; rename as appropriate
store_data, tplot_var, NEWNAME=new_name
tplot_var = new_name
END
'cnt_error1b': BEGIN
; a L2 product only
colors = 1
; rename with inserted class identifier
new_name = STRMID(tplot_var,0,breakpt)+'FSPC_'+$
STRMID(tplot_var,breakpt)
; search for existing variables, and delete
exists = tnames(new_name, cnt)
IF (cnt NE 0) THEN store_data, new_name, /DELETE
; rename as appropriate
store_data, tplot_var, NEWNAME=new_name
tplot_var = new_name
END
'cnt_error1c': BEGIN
; a L2 product only
colors = 1
; rename with inserted class identifier
new_name = STRMID(tplot_var,0,breakpt)+'FSPC_'+$
STRMID(tplot_var,breakpt)
; search for existing variables, and delete
exists = tnames(new_name, cnt)
IF (cnt NE 0) THEN store_data, new_name, /DELETE
; rename as appropriate
store_data, tplot_var, NEWNAME=new_name
tplot_var = new_name
END
'cnt_error2': BEGIN
; a L2 product only
colors = 1
; rename with inserted class identifier
new_name = STRMID(tplot_var,0,breakpt)+'FSPC_'+$
STRMID(tplot_var,breakpt)
; search for existing variables, and delete
exists = tnames(new_name, cnt)
IF (cnt NE 0) THEN store_data, new_name, /DELETE
; rename as appropriate
store_data, tplot_var, NEWNAME=new_name
tplot_var = new_name
END
'cnt_error3': BEGIN
; a L2 product only
colors = 1
; rename with inserted class identifier
new_name = STRMID(tplot_var,0,breakpt)+'FSPC_'+$
STRMID(tplot_var,breakpt)
; search for existing variables, and delete
exists = tnames(new_name, cnt)
IF (cnt NE 0) THEN store_data, new_name, /DELETE
; rename as appropriate
store_data, tplot_var, NEWNAME=new_name
tplot_var = new_name
END
'cnt_error4': BEGIN
; a L2 product only
colors = 1
; rename with inserted class identifier
new_name = STRMID(tplot_var,0,breakpt)+'FSPC_'+$
STRMID(tplot_var,breakpt)
; search for existing variables, and delete
exists = tnames(new_name, cnt)
IF (cnt NE 0) THEN store_data, new_name, /DELETE
; rename as appropriate
store_data, tplot_var, NEWNAME=new_name
tplot_var = new_name
END
'FSPC_Edges': BEGIN
; a L2 product only
colors = 6
END
ELSE: print, 'no matches for: ', tplot_var
ENDCASE
dprint, dlevel=4,'TPLOT_VAR: ', tplot_var
; report STATE type as 'none'? (e.g., neither POS nor VEL)
str_element, dl_str, 'data_att.st_type', 'none', /ADD
str_element, dl_str, 'data_att.units', unit, /ADD
str_element, dl_str, 'colors', colors, /ADD
str_element, dl_str, 'labels', labels, /ADD
; str_element, dl_str, 'min_value', max_fillvalue, /ADD ;(FSPC is immune from fill values, anyway)
IF (validmin_does_exist) THEN str_element, dl_str, 'min_value', validmin, /add
IF (validmax_does_exist) THEN str_element, dl_str, 'max_value', validmax, /add
str_element, dl_str, 'labflag', 1, /add
str_element, dl_str, 'ytitle', tplot_var, /ADD
str_element, dl_str, 'ysubtitle', '['+unit+']', /ADD
str_element, dl_str, 'datagap', 60, /ADD
store_data, tplot_var, data=d_str, limit=l_str, dlimit=dl_str, MIN=fill2nan
ENDIF
ENDFOR
ENDIF
END