;NAME:
; thm_apply_esa_mom_dtc
;PURPOSE:
; Corrects ESA on-board moments for dead time. Note that this will
; apply the dead-time correction to all of the moments for the given
; probe and species.
;CALLING SEQUENCE:
; thm_apply_esa_mom_dtc, probe=probe, instrument=instrument,
; out_suffix=out_suffix,in_suffix=in_suffix
;INPUT:
; All via keyword
;OUTPUT:
; None explicit, a number of tplot variables are created.
;KEYWORDS:
; probe='a','b','c','d' or 'e'
; instrument='peim' or 'peem', similar in use to the 'instrument'
; keyword for thm_part_moments
; use_esa_mode = 'f','r', or 'b', use this mode for the ESA data to get
; the dead time correction, the default is 'f'
; out_suffix= a suffix to add to new tplot variables for the
; moments. The default is the null string, so that
; variables are overwritten.
; in_suffix= if set, only variables with this suffix will be
; corrected, to avoid correcting variables that have been
; loaded without corrections.
;HISTORY:
; 13-may-2011, jmm, jimm@ssl.berkeley.edu
; 27-may-2011, jmm, dropped save_esa_vars keywords, to avoid suffix
; confusion, also passes out_suffix keyword through to
; thm_esa_dtc4mom
; 9-aug-2011, jmm, added in_suffix keyword
; $LastChangedBy: jimm $
; $LastChangedDate: 2014-05-20 16:42:39 -0700 (Tue, 20 May 2014) $
; $LastChangedRevision: 15178 $
; $URL: svn+ssh://thmsvn@ambrosia.ssl.berkeley.edu/repos/spdsoft/trunk/projects/themis/spacecraft/particles/moments/thm_apply_esa_mom_dtc.pro $
;-
Pro thm_apply_esa_mom_dtc, probe = probe, instrument = instrument, $
out_suffix = out_suffix, $
in_suffix = in_suffix, $
use_esa_mode = use_esa_mode, $
_extra = _extra
vprobes = ['a', 'b', 'c', 'd', 'e']
If(keyword_set(probe)) Then Begin
probes = thm_check_valid_name(strlowcase(probe), vprobes, /include_all)
If(is_string(probes) Eq 0) Then Begin
dprint, 'No valid probe input: '+probe
Return
Endif
Endif Else probes = vprobes
vinstruments = ['peim', 'peem']
If(keyword_set(instrument)) Then Begin
instruments = thm_check_valid_name(strlowcase(instrument), $
vinstruments, /include_all)
If(is_string(instruments) Eq 0) Then Begin
dprint, 'No valid instrument input: '+instrument
dprint, 'Use peim or peem'
Return
Endif
Endif Else instruments = vinstruments
species = strmid(instruments, 2, 1) ;i or e
If(is_string(use_esa_mode)) Then Begin
mode = strlowcase(strcompress(use_esa_mode, /remove_all))
Endif Else mode = 'f'
If(keyword_set(out_suffix)) Then osfx = out_suffix Else osfx = ''
If(keyword_set(in_suffix)) Then isfx = in_suffix Else isfx = ''
;For each probe
; vv = ['density', 'flux', 'mftens', 'eflux', 'velocity', $
; 'ptens', 't3'] ;these are the moments with corrections
vv = ['density', 'flux', 'mftens', 'eflux', 'velocity', $
'ptens', 'ptot'] ;these are the moments in L1 files
For j = 0, n_elements(probes)-1 Do Begin
sc = probes[j] & thx = 'th'+sc
init_dtc_vars = 0b
;For each species
For i = 0, n_elements(instruments)-1 Do Begin
For k = 0, n_elements(vv)-1 Do Begin
mvk = thx+'_'+instruments[i]+'_'+vv[k]
mvk_0 = tnames(mvk+'*'+isfx) ;for suffixes
If(is_string(mvk_0) Eq 0) Then Begin
dprint, 'No variable: '+mvk
Endif Else Begin
For l = 0, n_elements(mvk_0)-1 Do Begin
get_data, mvk_0[l], data = d, dlimits = dl, limits = al
;check the data_att for the 'dead_time_corrected' tag
If(is_struct(dl)) Then Begin
str_element, dl, 'data_att', data_att, success = yes_data_att
If(yes_data_att) Then Begin
str_element, data_att, 'dead_time_corrected', success = yes_dtc
Endif Else yes_dtc = 0b
Endif Else yes_dtc = 0b
;if uncorrected then correct it
If(yes_dtc Eq 0) Then Begin
;Only call dtc4mom program once per probe, we do it here to avoid
;calling this for variables that have been corrected.
If(~init_dtc_vars) Then Begin
thm_esa_dtc4mom, probe = sc, out_suffix = out_suffix, $
use_esa_mode = use_esa_mode, _extra = _extra
init_dtc_vars = 1b
Endif
;here you now have dead time corrections, all that is needed it to
;interpolate the corrections and multiply by the appropriate variable
;data
dtcvar = thx+'_pe'+species[i]+mode+'_'+vv[k]+'_dtc'+osfx
dtc = data_cut(dtcvar, d.x)
dydtc = d.y*dtc
store_data, mvk_0[l]+osfx, data = {x:d.x, y:dydtc}, limits = al
;set data_att tag to avoid overcorrection
If(is_struct(dl)) Then Begin
If(yes_data_att Eq 0) Then data_att = {dead_time_corrected:1} $
Else str_element, data_att, 'dead_time_corrected', 1, /add
str_element, dl, 'data_att', data_att, /add
Endif Else dl = {data_att:{dead_time_corrected:1}}
store_data, mvk_0[l]+osfx, dlimits = dl
Endif; Else message, /info, 'Variable: '+mvk_0[l]+' Has already been corrected'
Endfor
Endelse
Endfor
Endfor
Endfor
;If you're in the GUI, delete the dead time corrections and the
;delta_time variables for moment calculation
If(xregistered('spd_gui') Ne 0) Then Begin
store_data, 'th?_pe??_delta_time', /delete
store_data, 'th?_pe??_*_dtc', /delete
Endif
Return
End