Weekly Report 3Dec2010

From RHESSI Wiki

Jump to: navigation, search

Contents

RHESSI Website Migration

I continued working on the RHESSI Website migration, adding content including video and slideshows. Most of the past week was spent working on the website. This involved figuring out how to edit typoscript to insert the extensions that have been uploaded. These include the slideshow, embedded video, and an rss news reader extensions, as examples. Most pages have preliminary content or links to final documents. The website should be ready for preliminary launch by the end of the week.

RHESSI Albedo Imaging Test

Pixon images were created for a flare on 5Nov2010 near the limb. The image was created with the following parameters:

The pixon image created with these parameters is shown below.

The pixon image of a flare near the limb on 5Nov2010

The pixon image shows a compact source near the limb with a much weaker source slightly to the south. The stronger compact source is of interest because we can use it as a test case to compare to the simulated data we have been using. The first test was checking the flux radially from the center of the compact source radially outward.

The plot below shows the flux as a function of the radial distance from the source center.

The flux at a given radial distance from the centroid of the compact source with the average value, the minimum, and the maximum, for the 5Nov2010 flare

The plot above shows the average value of the flux, the minimum, and the maximum values. The flux values after approximately 4 arcsec are due to the second weaker source. The more interesting aspect is the region from the source center out to 4 arcsec. The minimum value drops off quickly while the maximum maintains a fairly constant value until approximately 3 arcsec where we see a small rise in the maximum flux. This looks like the characteristic behavior we see with the simulated data near the limb.

The following plot shows the flux of the simulated data near the limb and near disk center. For a comparison to the above plot the purple traces showing the flux near the limb are the ones of interest.

The flux at given radial distance from the source centroid for a pixon image of simulated data with albedo near the limb and near disk center

The purple trace, showing the behavior of the simulated data near the limb, shows some of the characteristics of the real 5Nov2010 data. The minimum falls off quickly, while the maximum falls off much more slowly, with a small bump at 4 arcsec.

This looks like it merits further exploration.


RHESSI Clean Imaging Test

The final set of images for phase one of the RHESSI Imaging test were created. The clean image sets are below:

Clean Images D1 to D9

Clean Images D2 to D9

Goals for next week

Personal tools
Namespaces
Variants
Actions
Navigation
Toolbox