Detector 6

From RHESSI Wiki

(Difference between revisions)
Jump to: navigation, search
Line 9: Line 9:
* On 2014 August 14, the HV on D6 was raised to 4926V in an attempt to segment it.  This was successful, and D6 now operates as a segmented detector.  Since its segmentation is borderline as of Aug/Sept 2014, it commonly unsegments during and just after the SAA.
* On 2014 August 14, the HV on D6 was raised to 4926V in an attempt to segment it.  This was successful, and D6 now operates as a segmented detector.  Since its segmentation is borderline as of Aug/Sept 2014, it commonly unsegments during and just after the SAA.
-
* A threshold change shortly after the anneal was completed.  (Note this threshold change was requested before it was found that D6 had segmented.
+
* A threshold change shortly after the anneal was completed.  (Note this threshold change was requested before it was found that D6 had segmented.)
   G6 front slow to 0x50 (was 0x60) after 03:40 UTC
   G6 front slow to 0x50 (was 0x60) after 03:40 UTC

Revision as of 22:41, 4 September 2014

UPDATE IN PROGRESS

This page contains information about changes/issues for RHESSI detector 6 after the 2014 anneal. Detector updates from 2012-mid 2014 can be found here: Detector 6 anneal 2012

Contents

Notes

After the 2014 anneal, detector 6 began its reincarnated life as an unsegmented detector but segmented shortly after (see below).

 G6 front slow to 0x50 (was 0x60) after 03:40 UTC

D6 front slow LLD threshold history

post 2014 anneal 0x
2014-Aug-14 after 03:40 UTC 0x50 (was 0x60)

D6 front fast LLD threshold history

post 2014 anneal 0x

D6 rear slow LLD threshold history

post 2014 anneal 0x

D6 rear fast LLD threshold history

post 2014 anneal 0x

D6 HV history

post 2014 anneal 4510 V
2014-Aug-14 03:40 UTC 4926 V (was 4510 V)