Detector 6 anneal 2012

From RHESSI Wiki

(Difference between revisions)
Jump to: navigation, search
Line 1: Line 1:
-
No notable issues since the 2012 anneal.
+
Detector 6 had no notable issue since the 2012 anneal until the noise/livetime problem occurred in 2014 Jan.
 +
 
 +
On 2014 Jan 3, Hugh Hudson noticed that the attenuator system has been in state 3 for a few days. It turned out that, in Detector 6 (both front and rear), livetime was decreasing rapidly and preamp-reset and FAST LLD were also rapidly increasing (See also [[Tohban_Report_2014-01-08]]). Then, over the next few days, several adjustments were made to D6 high voltage and FAST threshold (both front and rear) as described below.
 +
 
 +
 
 +
* 2014 Jan 04: As a first step, D6 HV was lowered by 8 steps down to about 3800 V.
 +
   
 +
    14-004-06:54:40 /ihvdac detector=6, voltage=198
 +
 
 +
* 2014 Jan 05: The livetime kept decreasing rapidly and so the D6 HV was lowered again by another 20 steps down to 2671 V.
 +
   
 +
    14-005-08:14:37 /ihvdac detector=6, voltage=148  (2868 V)
 +
    14-005-08:16:00 /ihvdac detector=6, voltage=138  (2671 V)
 +
 
 +
* 2014 Jan 06: Previous commandings led to >90% livetime but the FAST LLD was still somewhat high compared to that of D1. Because lowering HV further could result in faster degradation of the detector and also because David Smith reported that the HV changes worsened the spectroscopy (See his email on Jan 5), it was decided not to lower HV anymore. Instead, the front fast threshold was raised from 0x22 (~ 8 keV) to 0x50 (~ 20 keV).
 +
 
 +
    14-006-08:03:32 /idpudumptabl dibtbl6
 +
    14-006-08:03:57 /idputable6 frontfastdac
 +
    14-006-08:04:08 /idpuload value=0x50
 +
 
 +
* 2014 Jan 08: The livetime has now reached ~98% and the FAST LLD reached its nominal level. However, it was noticed that the rear segment also had the same noise/livetime problem. Thus, rear fast threshold was raised from 0x45 (? keV) to 0x60 (? keV).
 +
 
 +
    14-008-07:35:20 /idputable6 rearfastdac
 +
    14-008-07:35:40 /idpuload value=0x55
 +
    14-008-07:36:03 /idputable6 rearfastdac
 +
    14-008-07:36:56 /idpuload value=0x60
 +
 
 +
* 2014 Jan 08: In the meantime, it was decided to bring back the HV as much as possible to avoid further degradation of the detector. Over the course of 2 passes, the HV was raised by 30 steps up to 3259 V.
 +
 
 +
    14-008-07:37:49 /ihvdac detector=6, voltage=148
 +
    14-008-07:39:15 /ihvdac detector=6, voltage=158 (3063 V)
 +
    14-008-09:15:22 /ihvdac detector=6, voltage=168 (3259 V)
 +
 
 +
* 2014 Jan 08: Because noise leveled seemed to have increased during the HV commandings, front fast threshold was briefly raised from ox50 to 0x64 then back to 0x50.
 +
 
 +
    14-008-09:18:13 /idputable6 frontfastdac
 +
    14-008-09:18:39 /idpuload value=0x64
 +
    14-008-09:24:57 /idputable6 frontfastdac
 +
    14-008-09:25:28 /idpuload value=0x50

Revision as of 23:46, 8 January 2014

Detector 6 had no notable issue since the 2012 anneal until the noise/livetime problem occurred in 2014 Jan.

On 2014 Jan 3, Hugh Hudson noticed that the attenuator system has been in state 3 for a few days. It turned out that, in Detector 6 (both front and rear), livetime was decreasing rapidly and preamp-reset and FAST LLD were also rapidly increasing (See also Tohban_Report_2014-01-08). Then, over the next few days, several adjustments were made to D6 high voltage and FAST threshold (both front and rear) as described below.


   14-004-06:54:40 /ihvdac detector=6, voltage=198
   14-005-08:14:37 /ihvdac detector=6, voltage=148   (2868 V)
   14-005-08:16:00 /ihvdac detector=6, voltage=138   (2671 V)
   14-006-08:03:32 /idpudumptabl dibtbl6
   14-006-08:03:57 /idputable6 frontfastdac
   14-006-08:04:08 /idpuload value=0x50
   14-008-07:35:20 /idputable6 rearfastdac
   14-008-07:35:40 /idpuload value=0x55
   14-008-07:36:03 /idputable6 rearfastdac
   14-008-07:36:56 /idpuload value=0x60
   14-008-07:37:49 /ihvdac detector=6, voltage=148
   14-008-07:39:15 /ihvdac detector=6, voltage=158 (3063 V)
   14-008-09:15:22 /ihvdac detector=6, voltage=168 (3259 V)
   14-008-09:18:13 /idputable6 frontfastdac
   14-008-09:18:39 /idpuload value=0x64
   14-008-09:24:57 /idputable6 frontfastdac
   14-008-09:25:28 /idpuload value=0x50