Detector 7 anneal 2012

From RHESSI Wiki

(Difference between revisions)
Jump to: navigation, search
Line 9: Line 9:
   14-147-16:57:00 /IDPULOAD VALUE=0x30
   14-147-16:57:00 /IDPULOAD VALUE=0x30
 +
* 2014 Jun 9: Since the attenuator logic is using G2 only, G7 front fast threshold was raised to see if that might allow G7 to be used again in the attenuator logic.
 +
  14-160-17:01:04 /IDPUDUMPTABL TABLE=DIBTBL7
 +
  14-160-17:01:15 /IDPULOAD VALUE=0x40
===D7 front slow LLD threshold history===
===D7 front slow LLD threshold history===
Line 22: Line 25:
|-  
|-  
| 2014-May-27 16:57:00 UTC || 0x30 (was 0x22)
| 2014-May-27 16:57:00 UTC || 0x30 (was 0x22)
 +
|-
 +
| 2014-Jun-09 17:01:05 UTC || 0x40 (was 0x30)
|}
|}

Revision as of 04:24, 10 June 2014

Contents

Notes

There was an arc that led to a long period of extended noise in D7. See Tohban_Report_2013-07-24 for details.

 D7 HV was stepped down by 10 steps because of this.  (HV adjustment was on July 24, 2013 (day 205) at 19:29:15 UTC).  HV after the stepdown was ~3800 V.  This made no change in the noise level.
 Update as of Aug. 7 2013: David has determined that the noise is not affecting D7 spectroscopy (although the calibration may have changed slightly), and livetime is not being significantly affected, so no further steps will be taken for now.
  14-147-16:56:42 /IDPUTABLE7 OFFSET=FRONTFASTDAC
  14-147-16:57:00 /IDPULOAD VALUE=0x30
  14-160-17:01:04 /IDPUDUMPTABL TABLE=DIBTBL7
  14-160-17:01:15 /IDPULOAD VALUE=0x40

D7 front slow LLD threshold history

post 2012 anneal 0x0C

D7 front fast LLD threshold history

post 2012 anneal 0x22
2014-May-27 16:57:00 UTC 0x30 (was 0x22)
2014-Jun-09 17:01:05 UTC 0x40 (was 0x30)

D7 rear slow LLD threshold history

post 2012 anneal 0x30

D7 rear fast LLD threshold history

post 2012 anneal 0x45