X-ray and gamma-ray spectroscopy

From RHESSI Wiki

(Difference between revisions)
Jump to: navigation, search
(Created page with "{{Infobox Nugget |name = Nugget |title=X-ray and gamma-ray spectroscopy |number=27 |first_author=Hugh Hudson |second_author=David Smith |publish_date=22 January 2006 }} [http:/...")
(Remarks)
(3 intermediate revisions not shown)
Line 6: Line 6:
|second_author=David Smith
|second_author=David Smith
|publish_date=22 January 2006
|publish_date=22 January 2006
 +
|next_nugget={{#ask: [[Category:Nugget]] [[RHESSI Nugget Index::28]]}}
 +
|previous_nugget={{#ask: [[Category:Nugget]] [[RHESSI Nugget Index::26]]}}
}}
}}
 +
==Introducing one of RHESSI's main purposes==
-
[http://sprg.ssl.berkeley.edu/~tohban/nuggets/?page=article&article_id=27 Link out to original article]
+
Reuven Ramaty, whose name adorns our satellite, specialized in astronomical gamma-ray spectroscopy. A reader may wonder how a photon so energetic as to penetrate inches of lead shielding can ever be tamed spectroscopically. RHESSI does this better than any previous astronomical instrument, and this nugget introduces the subject. RHESSI both images and makes high-resolution spectra simultaneously ("imaging spectroscopy"), but most of our previous nuggets have emphasized the imaging. We hope to have several future nuggets on some of the many observational results of the RHESSI spectroscopic capability.
 +
==Germanium detectors==
 +
 
 +
The key to RHESSI's spectroscopic success lies in the properties of "hyperpure" germanium, which has the property of converting energy deposition precisely and linearly into electric charge, which can then be amplified and processed. Such a counter has a prototype in the "proportional counter", which introduced to physics the idea of "non-dispersive spectroscopy," in which one measures the energy of individual photons rather than using prisms or gratings to sort the energies. Non-dispersive spectroscopy, although usually of lower resolution, has the multiplex advantage, meaning that RHESSI can measure all photons of any energy at all times; no spectral scanning is required.
 +
 
 +
So how do germanium (Ge) solid state detectors work? RHESSI carries nine large hyperpure Ge crystal detectors. When a photon deposits its energy within the detector, electron-hole pairs (charges) are produced. To sweep up these charges, one needs a strong electric field. The figure below shows the pattern of electric field lines resulting from the high voltage (-4000 V) applied to the outer surface of the detector:
 +
 
 +
Figure 1. The electric field in a RHESSI germanium (Ge) detector. The shape of the detector is that of a hollowed-out cylinder. The high voltage is applied at the outer (P+) contact, while the inner (N+) contact is split into two parts to collect electrons from the upper and lower regions of the crystal. The top of the detector points to the Sun.
 +
The electric field configuration effectively splits the detector into two separate sections, the front and rear. An interruption in the inner contact allows these to be read out through separate chains of electronics. One RHESSI Ge detector acts like two! The front detectors catch the lower energy (not so penetrating) X-rays, while very energetic (penetrating) gamma rays travel right through the front and are caught by the rear section. The front-back geometry of the segmentation thus serves to shield the rear part of the Ge from the flood of lower-energy X-rays always produced by a solar flare.
 +
 
 +
==Photon Energy==
 +
 
 +
The main reason to use germanium -- an expensive detector material that must be operated below 100K -- is its superb energy resolution. Photon energy can be measured to within about 1 keV for hard X-rays in the front segments (below about 200 keV) and to within about 2 to 5 keV in the rear segments. For an MeV photon, this is a very high accuracy! It not only allows solar gamma-ray lines to be identified with specific nuclear processes, it even allows their Doppler profiles to be studied, in analogy to optical spectroscopy. Figure 2 shows an intrinsically narrow solar gamma-ray line from RHESSI's first gamma-ray line flare.
 +
 
 +
 
 +
Figure 2. Solar line from neutron capture during deuterium formation, from the 23 July 2002 GOES X4.8 flare observed by RHESSI. The natural line is extremely narrow; the width observed is the instrumental resolution of RHESSI's germanium detectors.
 +
When a very energetic photon interacts with the Ge, several things can happen. The simplest process is that all of the energy of the photon is deposited inside the germanium volume (via the mechanisms of photoelectric absorption, Compton scattering, and electron/positron pair production). If one were to plot detected count energy versus true photon energy then this response would be diagonal. Unfortunately, life is not always that simple; often, you don't get all the energy of the photon. The following two images show the response matrix for the front and rear detectors.
 +
 
 +
 +
Figure 3a. A visual representation of the response matrix for the front detectors (left) and rear detectors (right). Note the energy range difference in the axes, since the fronts detect low energies (X-rays) while the rears detect the high energies (gamma-rays). The color display is logarithmic. Click for an image for a larger version.
 +
The non-diagonal response is quite complex and includes many different processes, though most of the response at low energies is actually in the "diagonal elements" of the matrix, the thin yellow line. Above a few hundred keV, the off-diagonal response makes up the majority of the counts.
 +
 
 +
Here are these plots again with specific features marked.
 +
 
 +
 +
Figure 3b. Same as figure 3a but with non-diagonal features marked. Click an image for a larger version.
 +
 
 +
In cases where the full energy is not collected, the incoming photon does one of the following:
 +
 
 +
 
 +
#Compton-scatters off of an electron and exits the detector leaving only a fraction of its energy. This accounts for most of the off-diagonal activity and the strong Compton edge.
 +
#Compton-scatters through a small angle in the grids (or anything else) and into the detector.
 +
#Compton-scatters through a large angle (backscatters) into the detector.
 +
#excites K-shell fluorescence peaks from nearby passive material, including the tungsten collimator grids (59 keV, 67 keV).
 +
#generates a germanium K-shell (~ 10 keV) fluorescence photon which escapes.
 +
#generates an electron and positron pair outside of the detectors; the positron subsequently annihilates on another electron, generating the line at 511 keV.
 +
#generates an electron and positron pair inside of the detector, with one or two of these annihilation photons escaping, giving two spectroscopic escape peaks.
 +
 
 +
==Remarks==
 +
 
 +
The purpose of this RHESSI science nugget was just to introduce some of the ideas behind X-ray and gamma-ray spectroscopy, which is a somewhat obscure subject in astrophysics because of its extraordinary difficulty. In spite of this difficulty, the off-diagonal effects can be rather well accounted for by a combination of simulations and laboratory measurements. Removing the effects of the off-diagonal response is part of the RHESSI software. Future science nuggets will discuss some of the observations made with this system.
 +
 
 +
[[Category:Nugget needs figures]][[Category:Nugget need cleaning]]
 +
 
 +
Biographical note: Hugh Hudson is at UC Berkeley, and David Smith is at UC Santa Cruz. We thank Richard Schwartz and Albert Shih for the lovely images of the response matrices.
 +
 
 +
[[Has observation by:: RHESSI| ]]
 +
[[Has article subject:: RHESSI]]
 +
[[Has article subject:: education]]

Revision as of 02:29, 18 September 2018


Nugget
Number: 27
1st Author: Hugh Hudson
2nd Author: David Smith
Published: 22 January 2006
Next Nugget: One small step for a photon...
Previous Nugget: Sunquakes: Seismic Transients from Solar Flares
List all



Contents

Introducing one of RHESSI's main purposes

Reuven Ramaty, whose name adorns our satellite, specialized in astronomical gamma-ray spectroscopy. A reader may wonder how a photon so energetic as to penetrate inches of lead shielding can ever be tamed spectroscopically. RHESSI does this better than any previous astronomical instrument, and this nugget introduces the subject. RHESSI both images and makes high-resolution spectra simultaneously ("imaging spectroscopy"), but most of our previous nuggets have emphasized the imaging. We hope to have several future nuggets on some of the many observational results of the RHESSI spectroscopic capability.

Germanium detectors

The key to RHESSI's spectroscopic success lies in the properties of "hyperpure" germanium, which has the property of converting energy deposition precisely and linearly into electric charge, which can then be amplified and processed. Such a counter has a prototype in the "proportional counter", which introduced to physics the idea of "non-dispersive spectroscopy," in which one measures the energy of individual photons rather than using prisms or gratings to sort the energies. Non-dispersive spectroscopy, although usually of lower resolution, has the multiplex advantage, meaning that RHESSI can measure all photons of any energy at all times; no spectral scanning is required.

So how do germanium (Ge) solid state detectors work? RHESSI carries nine large hyperpure Ge crystal detectors. When a photon deposits its energy within the detector, electron-hole pairs (charges) are produced. To sweep up these charges, one needs a strong electric field. The figure below shows the pattern of electric field lines resulting from the high voltage (-4000 V) applied to the outer surface of the detector:

Figure 1. The electric field in a RHESSI germanium (Ge) detector. The shape of the detector is that of a hollowed-out cylinder. The high voltage is applied at the outer (P+) contact, while the inner (N+) contact is split into two parts to collect electrons from the upper and lower regions of the crystal. The top of the detector points to the Sun. The electric field configuration effectively splits the detector into two separate sections, the front and rear. An interruption in the inner contact allows these to be read out through separate chains of electronics. One RHESSI Ge detector acts like two! The front detectors catch the lower energy (not so penetrating) X-rays, while very energetic (penetrating) gamma rays travel right through the front and are caught by the rear section. The front-back geometry of the segmentation thus serves to shield the rear part of the Ge from the flood of lower-energy X-rays always produced by a solar flare.

Photon Energy

The main reason to use germanium -- an expensive detector material that must be operated below 100K -- is its superb energy resolution. Photon energy can be measured to within about 1 keV for hard X-rays in the front segments (below about 200 keV) and to within about 2 to 5 keV in the rear segments. For an MeV photon, this is a very high accuracy! It not only allows solar gamma-ray lines to be identified with specific nuclear processes, it even allows their Doppler profiles to be studied, in analogy to optical spectroscopy. Figure 2 shows an intrinsically narrow solar gamma-ray line from RHESSI's first gamma-ray line flare.


Figure 2. Solar line from neutron capture during deuterium formation, from the 23 July 2002 GOES X4.8 flare observed by RHESSI. The natural line is extremely narrow; the width observed is the instrumental resolution of RHESSI's germanium detectors. When a very energetic photon interacts with the Ge, several things can happen. The simplest process is that all of the energy of the photon is deposited inside the germanium volume (via the mechanisms of photoelectric absorption, Compton scattering, and electron/positron pair production). If one were to plot detected count energy versus true photon energy then this response would be diagonal. Unfortunately, life is not always that simple; often, you don't get all the energy of the photon. The following two images show the response matrix for the front and rear detectors.


Figure 3a. A visual representation of the response matrix for the front detectors (left) and rear detectors (right). Note the energy range difference in the axes, since the fronts detect low energies (X-rays) while the rears detect the high energies (gamma-rays). The color display is logarithmic. Click for an image for a larger version. The non-diagonal response is quite complex and includes many different processes, though most of the response at low energies is actually in the "diagonal elements" of the matrix, the thin yellow line. Above a few hundred keV, the off-diagonal response makes up the majority of the counts.

Here are these plots again with specific features marked.


Figure 3b. Same as figure 3a but with non-diagonal features marked. Click an image for a larger version.

In cases where the full energy is not collected, the incoming photon does one of the following:


  1. Compton-scatters off of an electron and exits the detector leaving only a fraction of its energy. This accounts for most of the off-diagonal activity and the strong Compton edge.
  2. Compton-scatters through a small angle in the grids (or anything else) and into the detector.
  3. Compton-scatters through a large angle (backscatters) into the detector.
  4. excites K-shell fluorescence peaks from nearby passive material, including the tungsten collimator grids (59 keV, 67 keV).
  5. generates a germanium K-shell (~ 10 keV) fluorescence photon which escapes.
  6. generates an electron and positron pair outside of the detectors; the positron subsequently annihilates on another electron, generating the line at 511 keV.
  7. generates an electron and positron pair inside of the detector, with one or two of these annihilation photons escaping, giving two spectroscopic escape peaks.

Remarks

The purpose of this RHESSI science nugget was just to introduce some of the ideas behind X-ray and gamma-ray spectroscopy, which is a somewhat obscure subject in astrophysics because of its extraordinary difficulty. In spite of this difficulty, the off-diagonal effects can be rather well accounted for by a combination of simulations and laboratory measurements. Removing the effects of the off-diagonal response is part of the RHESSI software. Future science nuggets will discuss some of the observations made with this system.

Biographical note: Hugh Hudson is at UC Berkeley, and David Smith is at UC Santa Cruz. We thank Richard Schwartz and Albert Shih for the lovely images of the response matrices.