RHESSI Resumes Observations

From RHESSI Wiki

Jump to: navigation, search


Nugget
Number: 234
1st Author: Albert Shih
2nd Author: Säm Krucker
Published: September 1, 2014
Next Nugget: Which RHESSI Detectors?
Previous Nugget: Evidence for Nanoflare Heating
List all



Contents

Introduction

As announced in an earlier Nugget, RHESSI entered its fourth annealing in late June. This process is periodically necessary to rejuvenate the detectors from the effects of the radiation damage that accumulates gradually in orbit, and a still earlier Nugget explains the process in further detail.

We are happy now that the process is complete, and that RHESSI is functioning again in a satisfactory, although (as expected) not quite as well as in 2002!

Detectors

Of RHESSI's nine detectors, each of which can make images, we now have five (1, 3, 6, 8, and 9) that are segmented, meaning that they can operate simultaneously as X-ray and gamma-ray detectors. In this configuration, the front segments can observe both hard X-rays and soft X-rays (down to ~3 keV). The anneal has successfully restored the spectral resolution (~1 keV FWHM at X-ray energies) and the X-ray sensitivity of these five detectors. For X-ray spectroscopy, you would use one or more of these detectors.

The anneal did in fact also rejuvenate the other four detectors (2, 4, 5, and 7), but because they currently do not electronically segment, they have relatively worse spectral resolution and can only measure above ~20 keV. Even with these limitations, these detectors are still quite usable for the core of RHESSI science: hard X-ray imaging spectroscopy. In the future, as radiation damage accrues again in these detectors, it may actually become possible for a couple of them to operate segmented again.

Thus, the anneal has achieved goals (see below for examples of recent data), albeit with some loss of image quality at soft X-ray energies since only a subset of the detectors can be used. At this stage in RHESSI's precious life – anticipating a few more powerful flares in this cycle – we are happy to have the higher spectral resolution that the annealing allowed.

Imaging

In Figure 1 we show an image of SOL2014-08-24T12, an almost-X-class event that had interesting structures. The Figure shows that RHESSI can image, at high resolution, the hard X-ray footpoint sources, as well as capturing the soft X-ray coronal loop structure at high temperatures.

Fig. 1: Images of SOL2014-08-24T12 in hard and soft X-rays (RHESSI) superposed on an EUV context image from AIA.

Note the interesting difference between RHESSI's soft X-ray contours and the AIA structures: RHESSI is showing us a better representation of the energetically important loop structures, which differ substantially from the EUV appearance.

Spectroscopy

How well can RHESSI now do imaging spectroscopy? There is essentially no change as a result of the anneal above 20 keV, as Figure 2 shows. This is an example (one example for each RHESSI detector) of the spectrogram representation of the RHESSI data.

Fig. 1: Spectrogram representation of each RHESSI detector's response to the flare SOL2014-08-24T12, showing that each of the nine detectors properly sees >20 keV photons.

Conclusion

RHESSI is now back in business after its fourth anneal, which we deem to have been a great success. For the immediate future (hoping for X-class flares!) the use of RHESSI for high-resolution imaging spectroscopy in the hard X-ray range, and down to thermal energies, can proceed as before. As always, for careful work it is important to work with the individual detectors. For spectroscopy below ~20 keV, only use detectors 1, 3, 6, 8, and 9 for the moment. This list of segmented detectors is subject to possible future improvements, which we'll also announce in a Nugget.

Personal tools
Namespaces
Variants
Actions
Navigation
Toolbox