Detector 9 history/issues goes here.
+
* 15 Feb 2012: Final stages of the anneal, all detectors, are back to 4000 V, except for detector 9 (which showed some arcing after SAA passages).  
 +
 
 +
* 7 - 14 March 2012: Some noise was observed on detector 9. On March 8 at 01:24 UTC detector G9 HV was lowered by ten counts. Some sporadic noise was observed, but the detector appears to fixed it-self.
 +
 
 +
* 11 - 18 April 2012:
 +
** Rear fast threshold from 0x45 -> 0x60
 +
*** /IDPUDUMPTABL DIBTBL9
 +
*** /IDPUTABLE9 REARFASTDAC    ;Load address 0x262C
 +
*** /IDPULOAD VALUE=0x60  ;Byte 10, Rear Fast threshold